Call one of our experts today: 1-800-307-9218 1-800-307-9218
Contact Us

VFI-200 50 D Slow Polyurea Coating

VFI-200 50 D Slow Polyurea Coating is a two-component, 100% solids, spray-applied coating capable of high builds on metal, concrete, and masonry. It is best used for industrial applications when spraying on horizontal surfaces to create a structure that protects from chemicals, abrasion, and impact. Due to its slower speed, VFI-200 has less chance of creating a heavy surface texture, which is why it is perfect for spraying larger areas that need little to no texture. VFI also offers different formulas in medium (VFI-201) and fast (VFI-202) setting speeds based on application needs.

  • Low moisture sensitivity due to setting speed
  • High tensile strength and elongation increase durability and longevity
  • Slower speed reduces that chance of unwanted texture on large, flat surfaces
  • Will not crack or break from extreme temperature changes
  • Protects against chemical corrosion and resists repeated wearing to maintain original structure
  • 100% solids content means no VOCs, and it retains 100% of its thickness after curing
Physical Properties Test Method Test Results
Shore Hardness ASTM D2240 50 D
Tensile Strength ASTM D412 2,400 psi
Elongation at Break ASTM D412 400%
Tear Strength ASTM D624 425 pli
Abrasion Resistance ASTM D4060 N/A
Impact Resistance ASTM D256 N/A
Water Absorption N/A 1.50%
Weathering N/A Not UV Stable
Linear Shrinkage N/A N/A
Permeance N/A 0.69 perm
Adhesion Strength Prepared Steel/Prepared Concrete N/A 725 lbs/in2
Color N/A Black
Liquid Properties Test Method Test Results
Solids by Volume ASTM D2697 100%
Mix Ratio by Volume (A:B) N/A 1A:1B
Weight per Gallon A Side ASTM D2939 9.19 lbs/gal
Weight per Gallon B Side ASTM D2939 8.41 lbs/gal
Viscosity A Side ASTM D2196 500 cps
Viscosity B Side ASTM D2196 500 cps
Gel Time N/A 8 seconds
Tack Free Time N/A N/A
Cure to Handle N/A 8-24 hours
Recoat Time N/A 30 minutes
Full Cure N/A 48 hours
VOC N/A 0

Application Requirements

The material should be brought to a minimum temperature of 65°F before use. Apply the coating at a minimum of 30 mil passes. When applying additional coats, you must stay within the 30-minute open window. The slower speed of VFI-200 allows for easier recoating. VFI recommends applying a UV-stable topcoat once VFI-200 has fully cured for complete UV stability. Coated surfaces can be placed into service after a minimum cure of 24 hours.

Equipment

Apply the material to the prepared surface using a plural-component high-pressure spray rig capable of spraying at 2,500 psi and temperatures between 135°F-150°F. Gun tips will vary by the project and will need to be adjusted on-site. The following machines are capable of meeting these specifications:

  • Graco A-XP1 air sprayer provides up to 3,500 psi of constant pressure and 170°F with a 1.5 gal/min output and 210 ft hoses. Use with any Probler P2 or Fusion gun.
  • Graco Reactor 2 E-XP2 electric sprayer provides up to 3,500 psi of constant pressure and 190°F with a 2 gal/min output and 310 ft hoses. Use with any Probler P2 or Fusion gun.
  • Graco Reactor 2 H-XP2/XP3 hydraulic sprayers provide up to 3,500 psi of constant pressure and 190°F with 1.5 or 2.8 gal/min outputs and 310 or 410 ft hoses. Use with any Probler P2 or Fusion gun.
  • PMC PHX-2 or 25 hydraulic sprayers, ideal for small or medium-scale applications, provide up to 3,000 psi of constant pressure and 190°F with outputs just under 2 gal/min and 210-410 ft hoses. Use with the AP-2 Air Purge, PX-7 Mechanical Purge, or Xtreme Spray Gun.

Surface Preparation

All surfaces should be clean, dry, and free of dirt, dust, and debris. Use a pressure washer on hard-to-clean surfaces to remove grease and oil. Treat mildew, fungus, and algae spots with a concentrated chlorine solution. Sandblast or grind away any loose paint, rust, and scale. Make any needed repairs to the surface to ensure the coating performs to the desired effect. Concrete surfaces must be aged a minimum of 28 days before application.

Mixing

Before spraying, premix the Poly (B side) until uniform.

Cleanup

VFI recommends cleaning application equipment with xylene or MEK. When flushing out spray lines, use VFI-8005 Pump Flush to remove all material from the hoses.

Storage/Shelf Life

Store between 60°F – 90°F in a clean, dry building. The shelf life of unopened containers is 12 months after the date of manufacture. Once opened, it should be used immediately. If you are storing after opening, the container must be nitrogen purged.

Precautions

VFI-200 contains isocyanate, which is irritating to the skin and toxic if inhaled as particulate matter. Avoid prolonged breathing of vapors and repeated skin contact. Do not add foreign material to the product. Use only with adequate ventilation. See Safety Data Sheet for complete safety information.

At VFI we offer solutions to all your project needs. With a talented onsite lab staff, we can customize our products to suit your application requirements. Contact us today to learn more about our custom solutions!

Volatile Free, Inc. (VFI)