VFI®-605-1 White Acrylic Coating

VFI®-605-1 White Acrylic Coating is a liquid applied coating that forms a seamless film using acrylic chemistry. VFI-605-1 provides UV stability and a waterproofing membrane in a water based single component package that cures at room temperature. VFI-605-1 Acrylic was specifically engineered for use in VOC sensitive areas and is resistant to high temperatures and oxidation.

White water based acrylic single component liquid applied roof coating or maintenance coating that forms a seamless film.

Features & Benefits

  • Water-Based Acrylic Elastomeric Coating
  • Seamless Liquid Applied Film with UV Stability
  • Superior Brightness for Maximum UV Reflectivity
  • Resistant to Oxidation and High Temperatures
  • Excellent Adhesion to Wide Variety of Substrates
  • Lower VOC Compliant Content Measuring <50 g/L
  • Exceptional Durability from a Trusted Manufacturer
  • Formulated for Use Over: Metal, Mod/Bit, BUR, Single-Ply, Concrete, Spray Foam

Related Industries:

Application Methods:

  • Spray
  • Brush
  • Roll

Available Packaging:

  • Tote
  • Drum
  • 5 Gallon

Product Details

  • Product Color: Standard color is white. Gray color are available in 640-1 acrylic elastomeric coating. For additional premium colors or color matching services contact Volatile Free, Inc.
  • UV Stability: This product is UV color stable and has long-term UV testing. For additional information contact Volatile Free, Inc.
  • Coverage/Thickness Requirement: See VFI specifications for specific coverage information or contact Volatile Free, Inc. for additional coverage/thickness requirements.
  • Storage Stability/Shelf Life: 18-month shelf life from date of manufacture when stored and sealed in unopened containers between 40°F - 75°F. Water based products must be protected from freezing. Material should be brought to a minimum temperature of 65°F before use.
  • Equipment: 605-1 acrylic elastomeric topcoat may be applied by sprayer, roller, or brush. If sprayed use single component spray equipment capable of maintaining a minimum constant spray pressure of 5000 psi. 5:1 transfer pump should be used with drums. Contact Volatile Free, Inc. for more information on any specific equipment questions and requirements.
  • Surface Preparation: Surface preparation depends on application and substrate being coated. All surfaces should be cleaned, prepped and free of any oils, dirt or films that could affect the product adhesion. Contact Volatile Free Inc. with any additional questions.
  • Mixing: Mixing until uniform is required on all material before use. Mix times may vary depending on volume and mixing method, please contact Volatile Free, Inc. for more information on any specific mixing questions and requirements.
  • Material Application: Material can be applied between 50°F - 120°F and the temperature must remain above 40°F until full cure. Apply only when rain or other moisture contamination is not present before fully cured. Standard application is a multiple coat method with 24 wet mil passes until the desired thickness is reached. The time between subsequent coats should not exceed 48 hours, but materials should be allowed to cure before applying the second coat. Material cure time will vary with temperature.
  • Primers: Volatile Free, Inc. recommends adhesion patch testing before use and additional adhesion patch testing with the chosen primer. The following are approved primers for use with 605-1 acrylic elastomeric topcoat. Contact Volatile Free, Inc. with any primer questions. • VFI-#11 • VFI-607 • VFI-1074-1 • VFI-3218
  • Cleanup: Preferred clean-up method is water. Please contact Volatile Free, Inc. for more information on clean-up of equipment and tools.
  • Thinning: Do not thin prior to application.
  • Precautions: See Safety Data Sheet for complete safety data. Do not add any foreign material to this product. Avoid prolonged breathing of vapors and prolonged or repeated skin contact. Use only with adequate ventilation.

VFI®-605-1 White Acrylic Coating Physical Properties

  • Tensile Strength (ASTM D 2370): 200 psi
  • Tear Strength (ASTM D-624): 80 pli
  • Aged Solar Reflectance of White (ASTM C-1549): 0.76
  • Aged Thermal Emittance of White (ASTM C-1371): 0.92
  • Fungi Resistance (ASTM G 21): 0
  • Permeance (ASTM D1653): 14 perms
  • Resistance to Wind Driven Rain (TT-C-555B): Pass
  • Water Swelling (ASTM D 471): 20.00%
  • Appearance After 1000 hours Accelerated Weathering (ASTM D4798): Pass
  • Low Temperature Flex (ASTM D522): Pass
  • Appearance after 1000 hrs accelerated weathering (ASTM D4798): Pass

VFI®-605-1 White Acrylic Coating Liquid Properties

  • Solids by Weight (ASTM D 1644): 61.00%
  • Solids by Volume (ASTM D2697): 57.00%
  • Liquid Density (ASTM D 2939): 10.90 lbs/gal
  • Specific Gravity: 1.30 g/mL
  • VOC: <50 g/L

Systems Used In

Acrylic System

Volatile Free, Inc. provides a very functional and easy to apply Low VOC Acrylic System. Water based acrylic chemistry provides a low VOC and low-cost product with easy single component application methods. 605-1 elastomeric acrylic topcoat excels at providing a monolithic membrane to prevent leaks and is UV stable. We recommend using our 640-1 elastomeric acrylic basecoat as the basecoat underneath the 605-1 acrylic topcoat, because it is fully UV stable, and will not degrade before the topcoat is applied, and it comes in a gray color. Using a two-color system to apply the acrylic helps to ensure even coverage and give you greater ease in tracking what needs to be covered. The acrylic system provides a good low-cost alternative to silicone on a roof with proper sloping and drainage. 605-1 elastomeric acrylic topcoat is fully UV and color stable and can be made into many different premium colors, but the preferred and most energy efficient color is white. A primer is recommended over most substrates and will vary depending on what substrate is being coated.

Approvals

Applications

Above Grade Waterproofing

Above grade waterproofing is a massive industry that focuses on both commercial and residential segments and we have strived to provide chemical options for both...

Learn More

Liquid Applied Roofing

Leaky roofs cause expensive, time intensive, and intrusive work that affects the life of a building and the activity within. Several permanent solutions exist to...

Learn More

Resources

Product Data Sheets